CloudWatcher

Vista l'importanza di proteggere le attrezzature astronomiche dalla pioggia, la misurazione della copertura nuvolosa è una parte importante di un osservatorio automatizzato indipendente. Consente al sistema di rilevare la presenza di una copertura nuvolosa e, fino a un certo punto, di integrare le informazioni delle condizioni di osservazione quando le nuvole sono assenti. 
Questo strumento, insieme alle stazioni e ai rilevatori di fulminazioni, permette di rilevare le condizioni meteorologiche sul sito del KWOS.

Dopo aver sperimentato l'autocostruzione, ho scelto di acquistare il "Cloud Watcher" della Lunatico Astronomia, corredato, da poco, del Solo
(Un ringraziamento speciale a Debora Sanchez e Jaime Alemany per la loro disponibilità e professionalità)

 

 

 

 

How the sensor works.

Sloan, Shaw and Williams (1955) have provided data which show that infra red measurements of the sky at wavelengths above5 µm (in particular between 8 µm and 14 µm) are sensitive to the presence of clouds. The presence of clouds produces an enhanced signal (which corresponds to an approximate black body spectrum at about ground temperature) above that from the clear sky. There is also an effect of atmospheric humidity which can produce enhanced signals particularly at low elevations. Inexpensive infra red sensors are now available which make all-sky or limited direction cloud monitoring possible without detector cooling systems and thus have low current drain with simplified design constraints.

Both clouds and water vapor absorb and re-emit radiation in discrete bands across the infrared spectrum. This permits infrared radiometers, including those configured as IR thermometers, to detect clouds, which are warmer than the clear sky, and water vapor, (Sloan, Shaw and Williams, 1955). Werner (1973) described the use of an infrared thermometer to detect clouds. The thermometer's IR sensor was a thermistor bolometer responsive to 9.5 to 11.5 μm. Today IR thermometry is used to detect the presence and temperature of clouds for meteorological research (Morris and Long, 2006). Both professional and amateur astronomers employ various IR sensors and IR thermometers to detect clouds that might interfere with their observations. For example, the Portable Cloud Sensor (Boltwood Systems Corporation) measures the sky temperature by means of a thermopile that responds to IR in a band from 8 to 14 μm (Thompson,9 2005).

Idso (1982) proposed the theory of measuring water vapor pressure by pointing at the cloud-free zenith sky an infrared thermometer sensitive to a band from 10.5 to 12.5 μm. He successfully tested his theory by conducting field tests.

Recently Maghrabi and Clay (2010) described a method for estimating PW in a clear sky based on the ambient temperature and the signal from an IR radiometer designed for cloud detection (Maghrabi et al., 2009) that they described as a single-pixel IR detector. The detector was a thermopile with a spectral response of from 6.6 to >20 μm. They compared their measurements of the cloud-free zenith sky with PW measured by a GPS receiver 30 km north of their location. From October 2002 to July 2004 their IR system provided an estimate of PW with a root mean square (rms) difference of 2.31mm from the GPS PW.

What I have demonstrated with this project is how commercially available IR thermometers can function as IR radiometers that both detect the presence of clouds and provide a means for estimating PW with an rms difference with PW given by a professional (MICROTOPS II( sun photometer of as little as 2.68 mm. This result is within 15% of that obtained by Maghrabi and Clay (2010). The IR thermometer method requires no custom electronics or expensive IR detectors and relies only on a battery-powered, handheld instrument.

Nor is an ambient temperature measurement necessary, for IR thermometers incorporate temperature compensation circuitry that corrects for changes in the ambient temperature. This is usually implemented by employing a 2-element detector, one element being shielded from the source of IR being monitored and the other being exposed to the source of IR. The IR thermometer method is very inexpensive, and the second best results described below were from a $20 instrument about the size of a pocket flash memory drive (Kintrex 401).
 

This Clouds Detector Sensor uses a thermopile sensor (MLX90614 family)directed to zenith. This sensor integrates radiation over the 120° of the sky. Clear view to the sky is important because any terrestrial objects can cause parasite IR radiation.
In fact two zones are measured by the thermopile sensor each with approximately 90° FOV.

References

Forrest M. Mims II, Lin Hartung Chambers, David R. Brooks, 2010 - Measuring Total Column Water Vaporby Pointing an Infrared Thermometer at The Sky
A. Maghrabi, R. Clay - Results from a simple infrared cloud detector

I really apologize for not having cited you before!